Neurobionplus
Home About Journal AHEAD OF PRINT Current Issue Back Issues Instructions Submission Search Subscribe Blog    
Login 

Users Online: 488 
Print this page  Email this page Small font sizeDefault font sizeIncrease font size 
ORIGINAL ARTICLE

Measurement of the whole and midsubstance femoral insertion of the anterior cruciate ligament: The comparison with the elliptically calculated femoral anterior cruciate ligament footprint area


1 Department of Orthopedic Surgery, Nihon University Hospital, Tokyo, Japan
2 Department of Functional Morphology, Nihon University School of Medicine, Tokyo; Department of Orthopaedic Surgery, Kamimoku Hot Springs Hospital, Minakami, Japan
3 Department of Functional Morphology, Nihon University School of Medicine, Tokyo, Japan

Correspondence Address:
Takanori Iriuchishima,
Department of Orthopaedic Surgery, Kamimoku Hot Springs Hospital, Minakami
Japan
Login to access the Email id

Source of Support: None, Conflict of Interest: None

DOI: 10.4103/ortho.IJOrtho_434_18

Purpose: The purpose of this study was to measure the detailed morphology of the femoral anterior cruciate ligament(ACL) footprint. The correlation and the comparison between the measured area and the area which mathematically calculated as elliptical were also evaluated. Materials and Methods: Thirty nine nonpaired human cadaver knees were used. The ACL was cut in the middle, and the femoral bone was cut at the most proximal point of the femoral notch. The ACL was carefully dissected, and the periphery of the ACL insertion site was outlined on both the whole footprint and the midsubstance insertion. Lateral view of the femoral condyle was photographed with a digital camera, and the images were downloaded to a personal computer. The area, length, and width of the femoral ACL footprint were measured with Image J software(National Institution of Health). Using the length and width of the femoral ACL footprint, the elliptical area was calculated as 0.25π(length×width). Statistical analysis was performed to reveal the correlation and the comparison of the measured and elliptically calculated area. Results: The sizes of the whole and midsubstance femoral ACL footprints were 127.6±41.7 mm2 and 61±20.2 mm2, respectively. The sizes of the elliptically calculated whole and midsubstance femoral ACL footprints were 113.9±4.5 mm2 and 58.4±3 mm2, respectively. Significant difference was observed between the measured and the elliptically calculated area. In the midsubstance insertion, significant correlation was observed between the measured and the elliptically calculated area(Pearson's correlation coefficient=0.603, P =0.001). However, no correlation was observed in the whole ACL insertion area. Conclusion: The morphology of the femoral ACL insertion resembles an elliptical shape. However, due to the wide variation in morphology, the femoral ACL insertion cannot be considered mathematically elliptical.

  Search Pubmed for
 
    -  Iwama G
    -  Iriuchishima T
    -  Horaguchi T
    -  Aizawa S
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed86    
    PDF Downloaded4    

Recommend this journal