Complex tibial plateau fractures treated by hybrid external fixation system: A correlation of followup computed tomography derived quality of reduction with clinical results


1 First Orthopaedic Department, Gennimatas General Hospital, Cholargos, Athens, Greece
2 Fourth Department of Orthopaedics and Traumatology, KAT Hospital, Kifissia, 2 Nikis Street, 145 61, Athens, Greece

Click here for correspondence address and email

Date of Web Publication6-Mar-2018
 

   Abstract 


Background: Tibial plateau fractures are common due to high energy injuries. The principles of treatment include respect for the soft tissues, restoring the congruity of the articular surface and reduction of the anatomic alignment of the lower limb to enable early movement of the knee joint. There are various surgical fixation methods that can achieve these principles of treatment. Recognition of the particular fracture pattern is important, as this guides the surgical approach required in order to adequately stabilize the fracture. This study evaluates the results of the combined treatment of external fixator and limited internal fixation along with the advantages using postoperative computed tomography (CT) scan after implant removal. Materials and Methods: 55 patients with a mean age of 42 years (range 17–65 years) with tibial plateau fracture, were managed in our institution between October 2010 and September 2013., Twenty fractures were classified as Schatzker VI and 35 as Schatzker V. There were 8 open fractures (2 Gustilo Anderson 3A and 6 Gustilo Anderson 2). All fractures were treated with closed reduction and hybrid external fixation (n = 21/38.2%) or with minimal open reduction internal fixation and a hybrid system (n = 34/61.8%). After the removal of the fixators, CT-scan was programmed for all the cases, for correlation with the results. At final followup, the American Knee Society Score (AKSS) was administered. Results: All patients were evaluated with a minimum of 12 months (range 12–21 months) followup. Average time to union was 15.5 weeks (range 13–19 weeks). The postoperative joint congruity as evaluated in the postoperative CT-scan was <2 mm of articular step-off in 8 patients (14.5%), between 2 and 4 mm in 18 patients (32.7%) and over 4 mm in 29 (52.7%). The injured limb mechanical axis was restored within 5° compared to the contralateral limb in 36 cases (65%) and with an angulation >5° in 19 cases (35%). Patients with residual joint depression <3.5 mm had a 95% chance of having excellent AKSS knee score results and 80% chance of having excellent AKSS function scores. On the other hand, residual joint depression of >4.5 mm displayed a 100% chance of getting poor-fair scores both in AKSS knee and AKSS function score. The association of a postoperative mechanical axis within 5° of the contralateral limb and improved knee scores was statistically significant for the AKSS function and total scores but not for the AKSS knee score. The AKSS was negatively correlated with postoperative joint depression magnitude which was statistically significant. Only the amount of joint collapse was verified as a prognostic factor in a multivariate logistic regression analysis. Conclusions: The postoperative CT-scan shows important information about bone healing, and an exact image of the reduction and the shaft alignment. Postoperative radiographs may have led to an underestimation of the degree of residual displacement. On the contrary, CT-scan demonstrates the exact grade of articular displacement and depending on CT-scan results one can better manage the postoperative rehabilitation.

Keywords: Joint congruity, postoperative computed tomography scan, tibilal plateau fractures, hybrid fixation
MeSH terms: Tibial fractures, CAT scanners, x-ray, Ilizarov technique

How to cite this article:
Kateros K, Galanakos SP, Kyriakopoulos G, Papadakis SA, Macheras GA. Complex tibial plateau fractures treated by hybrid external fixation system: A correlation of followup computed tomography derived quality of reduction with clinical results. Indian J Orthop 2018;52:161-9

How to cite this URL:
Kateros K, Galanakos SP, Kyriakopoulos G, Papadakis SA, Macheras GA. Complex tibial plateau fractures treated by hybrid external fixation system: A correlation of followup computed tomography derived quality of reduction with clinical results. Indian J Orthop [serial online] 2018 [cited 2019 Dec 9];52:161-9. Available from: http://www.ijoonline.com/text.asp?2018/52/2/161/226715



   Introduction Top


Complex tibial plateau fractures are usually high energy injuries presenting with significant articular and soft tissue damage in a major weight bearing joint. The restoration of the articular surface, joint stability, and axis is technically demanding. The soft tissue damage associated with the injury severity, only adds to the challenge of optimizing outcomes for these injuries.[1]

The original approach to these injuries was an open reduction of the fragments and internal fixation with plates and screws.[2],[3] The advantage of anatomic reduction and stable fixation that allows early joint motion is, however, frequently overshadowed by soft tissue complications.[4],[5],[6] The effect of the surgical trauma on compromised soft tissues leads to wound infection, a devastating complication associated with an increased reoperation rate and poor outcomes.[7],[8] To address these concerns, the use of a closed or limited open reduction with a hybrid ring fixator or ring frame has been advocated.[9],[10],[11],[12]

The purpose of this prospective case series was to evaluate the radiological and clinical outcomes after treatment of complex proximal tibial fractures with the use of a hybrid external fixator utilizing a pre- and postoperative computed tomography (CT) scan and the American Knee Society Score (AKSS).


   Materials and Methods Top


55 consecutive patients with 55 complex tibial plateau fractures treated by a hybrid external fixator between October 2010 and September 2013 in our institutions were enrolled in this study. All the cases were operated by senior surgeons (KK, PS).

All patients over 17 years of age with Schatzker Type V or VI tibial plateau fractures were included in the study. Exclusion criteria were multi-ligamentous instability that required a knee-spanning external fixator, patients that required a damage control approach due to vascular insult, bilateral injury, ipsilateral femoral fracture, preexisting knee arthritis, pathological fractures, and nonindependent preinjury ambulatory status.

64 fractures in 64 patients were identified during this period. Six patients had preexisting knee arthritis, two had impaired knee function due to previous strokes and one had vascular injury. These 9 patients were excluded from the study. There was a male predominance in the group with 31 male and 24 female patients and the mean age was 42 years (range 17–65 years). Twenty fractures were classified as Schatzker type VI and 35 as Schatzker type V. There were 8 open fractures (2 Gustillo Anderson 3A and 6 Gustillo Anderson 2) [Table 1]. The study protocol was approved by our institutions' ethics and scientific boards.
Table 1: Clinical details of patients

Click here to view


All patients underwent standard anteroposterior and lateral knee radiographs, performed in the emergency department [Figure 1]a. In addition, all patients underwent CT scans with coronal [Figure 1]b and axial [Figure 1]c reconstruction to evaluate the degree and location of articular comminution and joint depression, articular step-off, and identify main fragments on which to build a stable construct and place wires.
Figure 1: Preoperative anteroposterior (a) lateral (b) views and axial CT scan (c,d) showing proximal tibial fracture

Click here to view


Operative procedure

Prophylactic antibiotics were administered intravenously in all cases. All open fractures (n = 8) received antibiotic doses like this for the first day, a combination of the second generation cephalosporin with an aminoglycoside and subsequently replaced according to the culture results. Both open and closed fractures received preoperatively a single dose of teicoplanin. Patients who had an open wound received antibiotic treatment for a minimum of 5 days.

Surgery was performed under spinal or general anesthesia. Closed reduction was attempted under fluoroscopic guidance with ligamentotaxis either by means of fracture table traction or by an assistant, and gentle direct pressure and where needed, minimal open reduction or articular surface elevation with a tamp through a cortical window, followed by lag screw insertion. The articular blocks were then fixed to the shaft by a hybrid external fixator with a standard Ilizarov ring proximally and Schanz screws distally [Figure 2].
Figure 2: (a,b,c) Fluoroscopic images showing minimal invasive internal fixation and hybrid fixation in proximal tibial fracture and clinical photographs (d,e) showing fixation in situ

Click here to view


Each limb was strictly elevated until soft tissue edema was no longer a concern. Postoperatively, patients were encouraged to begin range of motion exercises immediately and physiotherapy was initiated during instay and continued postdischarge. Patients and caretakers were trained and instructed on pin toilette. All patients were nonweight bearing for 6 weeks postoperatively, and depending on articular surface comminution, were allowed to weight bear progressively from the 6th or 8th week. Full weight bearing was deferred until radiological or clinical signs of healing were observed.

Patients were followed up with serial radiographs in the outpatient department until clinical and radiographic union as defined by pain-free weight bearing and callus on three of four cortices. After fracture healing, the external fixator was removed and the postoperative CT-scan performed. All patients were followed up at weekly postoperative visits until fixator removal and at monthly intervals thereafter for a minimum of 1 year postoperatively (range 12–21 months) when the knee score evaluation was performed [Figure 3]a,[Figure 3]b,[Figure 3]c,[Figure 3]d.
Figure 3: Preoperative radiographs anteroposterior (a) and lateral view (b) showing proximal tibial fracture Schatzker type VI (c,d) Anteroposterior and lateral view radiographs after hybrid external fixator and minimal internal fixation removal

Click here to view


Subsequently, the fixator was removed and they had a CT-scan of their knee. At their final appointment, they were evaluated with the AKSS scores.[13]

The radiographs and CT-scans were reviewed documenting: alignment, articular depression in millimeters and step-off by the senior authors (KK, PS) along with a senior radiologist.

Statistical analysis

Statistical analysis was performed using the Statistical Package for the Social Sciences (SPSS) statistical package version 17 (SPSS Inc., Chicago, IL, USA). Data are expressed as mean ± standard deviation or median (interquartile range) for quantitative data and as percentages for qualitative data. The Kolmogorov–Smirnov test was utilized for normality analysis of the parameters. The analysis of quantitative variables between compared groups was performed using the one-way ANOVA model. Pairwise comparisons performed using the Bonferroni test. Kruskal–Wallis test and Mann–Whitney test were used in case of violation of normality. The correlation between qualitative variables was performed using the Chi-square test. Correlation between quantitative variables was examined using the Pearson's or Spearman's correlation coefficient. A receiver operating curve (ROC) analysis was conducted to determine the diagnostic ability and obtain cut off levels of joint collapse number for the classification of patients as excellent and no excellent according to AKSS knee and AKSS function scores by calculating the respective areas under the curve with their standard error and 95% confidence interval. The diagnostic ability of the joint alignment for the classification of patients as excellent and no excellent according to AKSS knee and AKSS function scores was evaluated using the sensitivity and specificity values multiple linear and logistic regression analysis with enter method was performed using as dependent variables the AKSS knee and AKSS function scores in quantitative and qualitative form and as independent variables the joint collapse number and joint alignment. All tests were two-sided, statistical significance was set at P < 0.05.


   Results Top


All fractures were treated with closed reduction and hybrid external fixation (21 fractures38.2%) or with minimal open reduction and a hybrid system (34 fractures/61.8%). Postoperative length of stay at hospital average was 4.2 days (range 3 to 6 days). Union was defined as pain-free weight bearing, and radiographs showing callus in minimum 3 cortices was observed. Average time to union was 15.5 weeks (range 13–19) [Figure 4]a and [Figure 4]b. There were 9 cases of pin tract infection treated with oral antibiotics and aggressive pin toilette but no deep wound infections or septic arthritis. We observed no compartment syndromes or deep vein thrombosis.
Figure 4: Postoperative CT scan in coronal (a) and axial plane (b) showing united proximal tibial fracture

Click here to view


The AKSS knee score was good or excellent in 22 patients overall (40%) and poor or fair in 23 patients (60%) with a mean value of 73. The AKSS function score was good or excellent in 35 patients (64%) and poor or fair in 20 (36%) with a mean value of 75 [Table 2].
Table 2: Patient knee scores distribution

Click here to view


The postoperative joint congruity as evaluated in the postoperative CT-scan was <2 mm of articular step-off in 8 patients (14.5%), between two and four mm in 18 patients (32.7%) and above 4 mm in 29 (52.7%). The injured limb joint alignment was restored within 5° compared to the contralateral limb in 36 cases (65%) and with an angulation >5° in 19 cases (35%). The AKSS was negatively correlated with postoperative joint depression magnitude was statistically significant [Table 3].
Table 3: Correlation of the American Knee Society Score with postoperative joint depression

Click here to view


ROC analysis showed that patients with residual joint depression <3.5 mm had a 95% chance of having excellent AKSS knee score results and 80% chance of having excellent AKSS function scores. On the other hand, residual joint depression of >4.5 mm displayed a 100% chance of getting poor fair scores both in AKSS knee and AKSS function score.

The association of a postoperative joint alignment within 5° of the contralateral limb and improved knee scores was statistically significant for the AKSS function and total scores but not for the AKSS knee score [Table 4].
Table 4: Correlation of the American Knee Society Score with postoperative joint alignment

Click here to view


Patients with postoperative joint alignment within 5° of the contralateral limb were associated with better knee function score category (good-excellent vs. poor-fair). Sensitivity: 77%, Specificity: 55%, P = 0.021 [Table 5]. However, only the amount of joint collapse was verified as a prognostic factor in a multivariate logistic regression analysis (excellent vs. no excellent and poor-fair vs. excellent).
Table 5: Correlation of the American Knee Society Score function score categories with postoperative joint alignment

Click here to view


Open fractures had on average lower AKSS scores (Gustillo Anderson 2 134 vs. 149 overall), but this did not reach statistical significance due to the small number of cases.


   Discussion Top


The treatment of complex proximal tibial fractures is challenging, and till date, there is no clear consensus as to the ideal method of treatment. Data suggesting that minimally invasive or closed reduction and ring or hybrid external fixation is a safer equivalent to open reduction and internal fixation of Schatzker Type V and VI fractures have accumulated in the past decade.[11],[12],[14],[15]

The need of preoperative detailed imaging especially for these specific types of injuries has been mentioned by many authors.[16],[17],[18] Yang et al.[16] proposed a CT-based three-column classification system (TCCS) where posterior tibial plateau fractures were defined as a fracture with an independent fragment of the posterior column. The authors stated that the TCCS gives a better understanding of the fracture morphology and the injury mechanism, which determines the appropriate surgical management.[16] Furthermore, other investigators agree that this classification system demonstrates a higher reliability and it can be used as a supplement to the conventional Schatzker classification, especially for complex and posterior comminuted tibial plateau fractures.[17],[18]

Various surgical techniques and approaches have been described, all with their own advantages and disadvantages. Likewise, numerous fixation options and devices are available, all with their own indications, contraindications, and potential problems.[19]

Open reduction and internal fixation with plates and screws has been termed as the “gold standard” treatment for these fractures so as to achieve a precise anatomic reduction of the joint surface which is solid enough to allow early mobilization; but these modalities of internal fixation, especially with a compromised soft tissue envelope and bulky metallic hardware, have been associated with complications.[8]

The role of external fixators, either half-pin or ring and wire, has been evaluated in various studies of comminuted complex tibial plateau fractures, and quite encouraging results have emerged.[9],[10],[11],[12],[15] To address reduction issues, several authors reported good results using a hybrid or circular frame combined with minimal open reduction and percutaneous screw fixation or even grafting, through a small skin incision in cases with severe comminution and metaphyseal osseous gap.[20],[21],[22]

Minimally invasive procedures with bone allograft and percutaneous screw fixation may be a treatment option with low risk of complications and a high level of satisfactory clinical and patient-reported outcomes for a selected patient group.[23] In a recent study by Elsøe et al.[23] 82% of the patients achieved anatomical reduction, which is in line with, or better than, other studies reporting this surgical method.[24],[25]

Moreover, no significant advantage of the newer open techniques has been reported in studies of sufficient power, as reflected in the recent review study by McNamara et al.[26] where patients treated with hybrid fixation were less likely to undergo secondary unplanned surgery.

In the present study, the postoperative joint depression showed a statistically significant correlation with the AKSS. Patients with residual joint depression >4.5 mm had poor or fair results, whereas all patients with joint depression <4 mm had good or excellent results. In the literature, there has been a wide range of residual displacement from 2 to 10 mm that has been considered acceptable.[27],[28],[29],[30] In a retrospective study by Rademakers et al.[31] the authors fractures found that an articular step-off of up to 4 mm did not differ statistically with a step-off less than 2 mm in radiographic and clinical outcomes at a mean followup of 14 years.[31] This is in accordance with our findings, but the study included all types of tibial plateau fractures and possibly does not account for the cartilage damage seen in higher energy fractures as in those of the present study. Kumar andWhittle[22] found better knee scores in short and midterm followup in patients that had a near anatomic restoration of the articular surface compared to patients with joint incongruity but did not quantify the amount of joint depression in their cases. An experimental study in sheep models by Trumble et al.[30] suggests that articular step-off of less than 2 mm is critical for good outcomes. They found that joint contour improvement is possible in displaced articular fragments if the displacement is less than the articular cartilage thickness.[30] The importance of articular congruity restoration is highlighted in the study by Blokker et al.[32] where a residual step-off >5 mm was associated with unsatisfactory results. Bai et al.[33] performed a cadaveric biomechanical study loading lateral tibial plateau fracture models with varied degrees of articular showed the importance of reducing articular step-off and retaining the menisci.[33] Honkonen, on the other hand, found a poor correlation between articular irregularities and development of osteoarthritis highlighting the role of meniscal retention or repair and anatomical axis restoration in the optimization of oucomes.[27]

Our data show a statistically significant decrease in knee scores in patients with a nonanatomic restoration of the joint alignment, defined as a 5° change from the contralateral limb, but disagree with the effect of joint congruency on outcomes with the previous author. The weaker statistical correlation of the mechanical axis and outcomes compared to joint congruity could, however, be due to the shorter followup in our study; although, we are not aware of any high powered study comparing the relative importance of mechanical axis alignment versus joint congruity in terms of mid to long term outcome.

The effect of residual joint depression in the long term outcomes of patients treated with tibial plateau fractures has not been resolved in the literature. Houben et al.[34] demonstrated a bimodal distribution of knee function deterioration following a tibial plateau fracture. Their patients reported the most functional complaints in the first 3 years or after 6 years from treatment, with an improvement in subjective knee scores in years 3–6. Therefore, the duration and timing of followup play a critical role in the reported outcomes.

The value of radiographic arthritis measurements has been challenged in a study by Katsenis et al.[15] who followed up patients treated with small wire circular frames at 3 and 5 years postoperatively and found radiographic deterioration of the knee joint without significant deterioration of functional results. Conserva et al.[14] with a mean followup of 3 years (38 months) noticed a higher incidence of radiographic osteoarthritis in patients treated with external fixation for complex tibial plateau fractures than in patients treated with internal fixation. However, patients treated with external fixation had higher WOMAC scores, although this did not reach statistical significance.

The major strength of the present study is the elimination of methodological issues with radiographic measurements and interobserver variability by means of postoperative CT-scans. To assess the effect of articular congruity on outcomes, fracture reduction has to be measured in an accurate and reproducible manner. Plain radiographs have not been shown to allow for an accurate and reproducible measurement of articular joint depression and joint alignment. To our knowledge there has been no similar study correlating functional outcomes with CT-derived radiographic measurements for complex tibial plateau fractures.

The main limitation of the study is the relatively short followup of our patients, which does not allow for long term outcome prognosis.


   Conclusions Top


Based on our results, the use of hybrid external fixator for the treatment of complex tibial plateau fractures is safe and effective in terms of low rates of complication and good functional results. Attempts to restore the articular congruity and anatomical axis should be made, as an articular step-off of more than 4 mm is strongly correlated with worse outcomes. Malalignment in the coronal plane should be <5° compared to the contralateral limb to improve short-term functional outcomes.

We feel that further studies of higher power are needed to determine the effect of smaller articular step-off on short and midterm functional outcomes, and help elucidate the effect of level of surgeon and center expertise in the treatment outcomes of these challenging injuries.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Papagelopoulos PJ, Partsinevelos AA, Themistocleous GS, Mavrogenis AF, Korres DS, Soucacos PN. Complications after tibia plateau fracture surgery. Injury 2006;37:475-84.  Back to cited text no. 1
[PUBMED]    
2.
Schatzker J. Fractures of the tibial plateau. In: Schatzker J, Tile M, editors. Rationale of Operative Fracture Care. New York: Springer; 1987. p. 279-95.  Back to cited text no. 2
    
3.
Tscherne H, Lobenhoffer P. Tibial plateau fractures. Management and expected results. Clin Orthop Relat Res 1993;292 87-100.  Back to cited text no. 3
    
4.
Moore TM, Patzakis MJ, Harvey JP. Tibial plateau fractures: Definition, demographics, treatment rationale, and long term results of closed traction management or operative reduction. J Orthop Trauma 1987;1:97-119.  Back to cited text no. 4
[PUBMED]    
5.
Mallik AR, Covall DJ, Whitelaw GP. Internal versus external fixation of bicondylar tibial plateau fractures. Orthop Rev 1992;21:1433-6.  Back to cited text no. 5
[PUBMED]    
6.
Barei DP, Nork SE, Mills WJ, Henley MB, Benirschke SK. Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique. J Orthop Trauma 2004;18:649-57.  Back to cited text no. 6
[PUBMED]    
7.
Young MJ, Barrack RL. Complications of internal fixation of tibial plateau fractures. Orthop Rev 1994;23:149-54.  Back to cited text no. 7
[PUBMED]    
8.
Ruffolo MR, Gettys FK, Montijo HE, Seymour RB, Karunakar MA. Complications of high-energy bicondylar tibial plateau fractures treated with dual plating through 2 incisions. J Orthop Trauma 2015;29:85-90.  Back to cited text no. 8
    
9.
Gaudinez RF, Mallik AR, Szporn M. Hybrid external fixation of comminuted tibial plateau fractures. Clin Orthop Relat Res 1996;328 203-10.  Back to cited text no. 9
    
10.
Singh H, Misra RK, Kaur M. Management of proximal tibia fractures using wire based circular external fixator. J Clin Diagn Res 2015;9:RC01-4.  Back to cited text no. 10
    
11.
Piper KJ, Won HY, Ellis AM. Hybrid external fixation in complex tibial plateau and plafond fractures: An Australian audit of outcomes. Injury 2005;36:178-84.  Back to cited text no. 11
    
12.
Watson JT, Ripple S, Hoshaw SJ, Fhyrie D. Hybrid external fixation for tibial plateau fractures: Clinical and biomechanical correlation. Orthop Clin North Am 2002;33:199-209, ix.  Back to cited text no. 12
    
13.
Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 1989;248 13-4.  Back to cited text no. 13
    
14.
Conserva V, Vicenti G, Allegretti G, Filipponi M, Monno A, Picca G, et al. Retrospective review of tibial plateau fractures treated by two methods without staging. Injury 2015;46:1951-6.  Back to cited text no. 14
    
15.
Katsenis D, Dendrinos G, Kouris A, Savas N, Schoinochoritis N, Pogiatzis K. Combination of fine wire fixation and limited internal fixation for high-energy tibial plateau fractures: Functional results at minimum 5-year followup. J Orthop Trauma 2009;23:493-501.  Back to cited text no. 15
    
16.
Yang G, Zhai Q, Zhu Y, Sun H, Putnis S, Luo C. The incidence of posterior tibial plateau fracture: An investigation of 525 fractures by using a CT-based classification system. Arch Orthop Trauma Surg 2013;133:929-34.  Back to cited text no. 16
    
17.
Zhu Y, Yang G, Luo CF, Smith WR, Hu CF, Gao H, et al. Computed tomography-based three-column classification in tibial plateau fractures: Introduction of its utility and assessment of its reproducibility. J Trauma Acute Care Surg 2012;73:731-7.  Back to cited text no. 17
    
18.
Luo CF, Sun H, Zhang B, Zeng BF. Three-column fixation for complex tibial plateau fractures. J Orthop Trauma 2010;24:683-92.  Back to cited text no. 18
    
19.
Kokkalis ZT, Iliopoulos ID, Pantazis C, Panagiotopoulos E. What's new in the management of complex tibial plateau fractures? Injury 2016;47:1162-9.  Back to cited text no. 19
    
20.
Goff T, Kanakaris NK, Giannoudis PV. Use of bone graft substitutes in the management of tibial plateau fractures. Injury 2013;44 Suppl 1:S86-94.  Back to cited text no. 20
    
21.
Babis GC, Evangelopoulos DS, Kontovazenitis P, Nikolopoulos K, Soucacos PN. High energy tibial plateau fractures treated with hybrid external fixation. J Orthop Surg Res 2011;6:35.  Back to cited text no. 21
    
22.
Kumar A, Whittle AP. Treatment of complex (Schatzker Type VI) fractures of the tibial plateau with circular wire external fixation: Retrospective case review. J Orthop Trauma 2000;14:339-44.  Back to cited text no. 22
    
23.
Elsøe R, Larsen P, Rasmussen S, Hansen HA, Eriksen CB. High degree of patient satisfaction after percutaneous treatment of lateral tibia plateau fractures. Dan Med J 2016;63:A5174.  Back to cited text no. 23
    
24.
Sament R, Mayanger JC, Tripathy SK, Sen RK. Closed reduction and percutaneous screw fixation for tibial plateau fractures. J Orthop Surg (Hong Kong) 2012;20:37-41.  Back to cited text no. 24
    
25.
Mattiassich G, Foltin E, Scheurecker G, Schneiderbauer A, Kröpfl A, Fischmeister M. Radiographic and clinical results after surgically treated tibial plateau fractures at three and twenty two years postsurgery. Int Orthop 2014;38:587-94.  Back to cited text no. 25
    
26.
McNamara IR, Smith TO, Shepherd KL, Clark AB, Nielsen DM, Donell S, et al. Surgical fixation methods for tibial plateau fractures. Cochrane Database Syst Rev 2015;9 CD009679.  Back to cited text no. 26
    
27.
Honkonen SE. Degenerative arthritis after tibial plateau fractures. J Orthop Trauma 1995;9:273-7.  Back to cited text no. 27
    
28.
Weigel DP, Marsh JL. High-energy fractures of the tibial plateau. Knee function after longer followup. J Bone Joint Surg Am 2002;84-A:1541-51.  Back to cited text no. 28
    
29.
Duwelius PJ, Connolly JF. Closed reduction of tibial plateau fractures. A comparison of functional and roentgenographic end results. Clin Orthop Relat Res 1988;230 116-26.  Back to cited text no. 29
    
30.
Trumble T, Allan CH, Miyano J, Clark JM, Ott S, Jones DE, et al. Apreliminary study of joint surface changes after an intraarticular fracture: A sheep model of a tibia fracture with weight bearing after internal fixation. J Orthop Trauma 2001;15:326-32.  Back to cited text no. 30
    
31.
Rademakers MV, Kerkhoffs GM, Sierevelt IN, Raaymakers EL, Marti RK. Operative treatment of 109 tibial plateau fractures: Five- to 27-year followup results. J Orthop Trauma 2007;21:5-10.  Back to cited text no. 31
    
32.
Blokker CP, Rorabeck CH, Bourne RB. Tibial plateau fractures. An analysis of the results of treatment in 60 patients. Clin Orthop Relat Res 1984;182 193-9.  Back to cited text no. 32
    
33.
Bai B, Kummer FJ, Sala DA, Koval KJ, Wolinsky PR. Effect of articular step-off and meniscectomy on joint alignment and contact pressures for fractures of the lateral tibial plateau. J Orthop Trauma 2001;15:101-6.  Back to cited text no. 33
    
34.
Houben PF, van der Linden ES, van den Wildenberg FA, Stapert JW. Functional and radiological outcome after intraarticular tibial plateau fractures. Injury 1997;28:459-62.  Back to cited text no. 34
    

Top
Correspondence Address:
Dr. Spyridon P Galanakos
Fourth Department of Orthopaedics and Traumatology, KAT Hospital, Kifissia, 2 Nikis Street, 145 61, Athens
Greece
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ortho.IJOrtho_300_16

Rights and Permissions


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4]
 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4], [Table 5]



 

Top
 
 
 
  Search
 
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  
 


 
    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusions
    References
    Article Figures
    Article Tables
 

 Article Access Statistics
    Viewed1368    
    Printed12    
    Emailed0    
    PDF Downloaded139    
    Comments [Add]    

Recommend this journal