Neurobionplus
Home About Journal AHEAD OF PRINT Current Issue Back Issues Instructions Submission Search Subscribe Blog    
Login 

Users Online: 267 
Print this page  Email this page Small font sizeDefault font sizeIncrease font size 
KNEE SYMPOSIUM
Year : 2016  |  Volume : 50  |  Issue : 2  |  Page : 146-153

Autoclaved metal-on-cement spacer versus static spacer in two-stage revision in periprosthetic knee infection


Department of Orthopaedic Surgery, Wan Fang Hospital, School of Medicine, Taipei Medial University, Taipei, Taiwan, Taiwan

Correspondence Address:
Wei-Pin Ho
Department of Orthopaedic Surgery, Wan Fang Hospital, School of Medicine, Taipei Medial University, Taipei
Taiwan
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0019-5413.177587

Rights and Permissions

Background: Periprosthetic knee infection is troublesome for Orthopedic surgeons and a catastrophy for patients. Reported rates of periprosthetic joint infection following primary total knee arthroplasty (TKA) are 0.39–2%. Two stage revision arthroplasty, which has success rates exceeding 90%, has been the gold standard for treating subacute and chronic periprosthetic infection following TKA. Antibiotic spacers, a well established means of delivering local antibiotic therapy, maintain soft tissue tension during two stage revision arthroplasty. However, controversy remains around whether static or mobile antibiotic impregnated spacers are superior for treating infection following TKA. Various mobile spacers are available, including cement-on-cement, cement-on-polyethylene and metal-on-polyethylene. In this study, the efficacy of the modified metal-on-cement spacer, consisting of reinsertion of the autoclaved femoral component and implantation of antibiotic-loaded cement in the proximal tibia, is assessed. Materials and Methods: Records of 19 patients diagnosed as periprosthetic knee infection were reviewed in this retrospective study. Among these patients, 10 patients received first stage debridement with the autoclaved metal-on-cement spacer and 8 patients with the static spacer, who eventually underwent two-stage re-implantation, were listed in the final comparison. Patient demographics, infection eradication rates, average range of motion (ROM), surgical time and blood loss during the second-stage of the surgery, and Knee Society (KS) knee scores at last followup after revision total knee replacement were clinically evaluated. Results: At a minimum of 2-year followup after re-implantation, infection eradication rates, surgical times, blood loss during the second-stage of the surgery, and KS knee score after re-implantation were similar for the two groups. Patients receiving autoclaved metal-on-cement spacers had superior ROM after re-implantation compared to that of patients with static spacers. Conclusions: The autoclaved metal-on-cement spacer is an effective and simple method for two-stage re-implantation of a periprosthetic knee infection. Through this spacer, the good interim ROM can be achieved without the additional cost of prefabricated molds or new polyethylene tibial inserts. In addition, ROM after re-implantation is better than that with static spacers.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2458    
    Printed23    
    Emailed1    
    PDF Downloaded104    
    Comments [Add]    

Recommend this journal