Neurobionplus
Home About Journal AHEAD OF PRINT Current Issue Back Issues Instructions Submission Search Subscribe Blog    
Login 

Users Online: 439 
Print this page  Email this page Small font sizeDefault font sizeIncrease font size 
 


 
 Table of Contents    
CASE REPORT  
Year : 2012  |  Volume : 46  |  Issue : 6  |  Page : 718-720
Use of Huckstep nail in the periimplant femoral shaft fracture


Department of Orthopedic Surgery, Kangnam Sacred Heart, Hospital, College of Medicine, Hallym University, Seoul, Korea

Click here for correspondence address and email

Date of Web Publication3-Dec-2012
 

   Abstract 

87-year-old female underwent open reduction of distal femoral fracture and internal fixation with locking compression plate and bone graft. She was operated for ipsilateral proximal femoral fractures and stabilized by intramedullary interlocked nail 5 years ago. She developed stress fracture proximal to locked plate. We inserted Huckstep nail after removal of the previous operated proximal femoral nail without removing the remaining plate and screws. At 15 month followup the fractures have united. The Huckstep nail has multiple holes available for screw fixation at any level in such difficult situations.

Keywords: Femur, Huckstep nail, periimplant fracture, stress riser

How to cite this article:
Kim HK, Noh KC, Chung KJ, Hwang JH. Use of Huckstep nail in the periimplant femoral shaft fracture. Indian J Orthop 2012;46:718-20

How to cite this URL:
Kim HK, Noh KC, Chung KJ, Hwang JH. Use of Huckstep nail in the periimplant femoral shaft fracture. Indian J Orthop [serial online] 2012 [cited 2019 Dec 14];46:718-20. Available from: http://www.ijoonline.com/text.asp?2012/46/6/718/104240

   Introduction Top


Senile osteoporotic insufficiency or fragile fracture present difficult surgical challenge. The method of treatment is well established particularly in peritrochanteric fractures and femoral shaft fractures, but there is still a lot of ongoing debate about the fracture of distal part of the femur. Antegrade or retrograde nailing is less invasive and more physiologic, but anatomical reduction is difficult. On the other hand, plating is more appropriate for anatomical reduction in this area, but it leads to stress rising fracture in the proximal part of the plate. We report a case who were recently treated with locked compression plate for distal femoral fracture and developed a stress rising fracture proximal to the plate in early postoperative period in view of treatment dilemma.


   Case Report Top


An 87-year-old female patient had a comminuted spiral fracture of left distal femur [Figure 1]. She was treated in our hospital with closed reduction and intramedullary nailing (PFN, Synthes, Davos, Switzerland) for the left proximal femoral fracture 5 years ago. A bone density study with Q-CT before the operation revealed osteoporosis with T-score -4.4. After thorough preoperative evaluation, we performed open reduction and anatomical reduction using locking compression plate (LCP, Synthes) under general anesthesia. The tricalcium phosphate (β-TCP) synthetic bone graft substitute Polybone® (Hanmi, Seoul, Korea) was added at the fracture site because of intraoperative bony insufficiency [Figure 2]. The patient was discharged on a wheel chair on the 8 th day after the operation. During home care on the 9 th day after the operation, the patient reported pain mid thigh after a trivial fall while her family was moving her. On X-ray a fracture between the existing proximal femoral nail and fixed locking compression metal plate [Figure 3] was diagnosed. It was a stress riser fracture. We decided to insert Huckstep nail after removing proximal femoral nail. The Huckstep nail was being used during ankle fusion by us. Comparing the hole of Huckstep nail to be used with that of the LCP from the previous operation, we were sure that the hole of Huckstep nail corresponded with the one of LCP. Fortunately, we confirmed preoperatively that and we could insert at least two distal interlocking screws through the hole of plate with a lot of distal holes of Huckstep nail. The operation was performed in lateral decubitus position under fluoroscopy. We removed the existing proximal femoral nail. We inserted Huckstep nail connecting to guide and withdrew the existing screws by previous incision of distal under plate. We had some difficulty with reinsertion of the removed screws. We matched the two holes of plate and nail under fluoroscope and inserted Steinmann pin as a guide pin and reinserted the previous screws. Then, we inserted three threaded screws into a transverse hole with a washer in the proximal part [Figure 4]. We mobilised the patient on a wheelchair for 2 weeks after the operation, and she left the hospital after the stitches had been removed in the 2 nd week after the second operation. She was followed up for 15 months after she was discharged from the hospital [Figure 5].
Figure 1: Initial X-ray on the day of trauma shows supracondylar area fracture which is extended to the intraarticular area (a, b)

Click here to view
Figure 2: Postoperative anteroposterior (a) and lateral (b) radiographs of the left distal femur revealing a good reduction

Click here to view
Figure 3: X-rays of the thigh anteroposterior view (a) and lateral view (b) shows stress riser fracture between the distal tip of the previous nail and proximal tip of the LCP plate on the postoperative 8th day

Click here to view
Figure 4: Immediate postoperative anteroposterior (a) and lateral (b) radiographs of the left femur showing newly inserted Huckstep nail without removal of the previous LCP

Click here to view
Figure 5: Final followup at 15 months postoperative anteroposterior (a) and lateral (b) views of the left femur showing wellaligned and united previous fracture site

Click here to view



   Discussion Top


Periprosthetic fracture generally occurs after knee joint or hip joint replacement. The incidence is about 0.3-5.5% after knee replacement and up to 30% [1] after revision TKA. The periprosthetic fracture after total hip joint replacement is relatively rare compared with knee joint fracture and reported to be about 0.1-2%, and commonly occurs around a prosthesis tip. [2] The periimplantar fracture, which occurs around a plate or a nail, is caused when a plate tip and a nail tip act as a stress riser, particularly in aged people. In this case we inserted a plate for distal fracture which was not overlapping the proximal nail inserted for proximal fracture in the same bone otherwise the proximal nail should have been removed and then inserted by a longer nail inserted in a retrograde manner. We consider this as iatrogenic fracture which could have been prevented. In aged people, stress riser fracture must be considered before and after operation. Huckstep nail may be a very useful solution in such cases. In case of using a conventional nail, the number of holes in the distal part is limited and many recent designs of femoral nail are anatomical nails considering anterior bowing, so there are a lot of restrictions in making the hole in the distal part corresponding with the hole in a plate.

Developed and used first in 1967, Huckstep nail is usually available for the management of femoral nonunions, rigid immobilization for entire femoral shaft fracture, severe comminuted fracture, a fracture of both femoral shaft and neck, a patient for early weight bearing, a case which needs lengthening by bone graft due to bone cyst, knee, elbow, ankle joint arthrodesis, and difficult fracture of tibia and humerus. [3] Literature review shows that Kim et al. reported solid fixation by Huckstep nail in 19 cases of difficult femoral fracture [4] and Cho et al. reported good results from 15 cases. [5] Christie et al. reported good results from 120 femoral fractures, [6] and Kuo-an et al. and Choi et al. reported good results on using Huckstep nail in knee joint fusion. [7],[8] Thus, in most cases, it is being used in difficult femoral fracture or knee joint fusion. Hwang et al. presented a case report about treating Shepherd's crook deformity that occurred in fibrous dysplasia. [9]

Huskstep nail in periimplantar fracture like we used, has never been reported so far. Huckstep nail is four-sided, intramedullary compression nail of solid titanium. The material is α-β titanium alloy, a mix of 6% aluminum and 4% vanadium. It is very biocompatible because its modulus of elasticity is just about half of those of stainless steel and chrome cobalt. Also, it is about 1.1-1.8 times stronger than average femoral bones. Square cross section makes medullary blood supply better to help bone healing. Three kinds of diameters are available; the most common diameters of a nail are 12.5 mm, 11.5 mm and 10.5 mm. The whole length of a nail has 4.6-mm transverse holes at 15 mm intervals, where 4.5-mm fine thread screw should be inserted. In the proximal part, there are four oblique holes at an angle of 130°, which enable insertion of a lag screw at the neck of femur in the proximal fracture of femur. [3]

Periimplantar fracture is very challenging. Prediction and prevention are the most important in periimplantar fracture in aged people, and we may consider Huckstep nail if we need to conduct an operation again with plates and screws as they are. Of course, Huckstep nail has an advantage of having multiholes, but does not have a variety of lengths and diameters; and since it is a straight nail, there might be a lot of restrictions in severe femoral bowing of the aged. Since in case it was an early periimplantar fracture in previous fracture distal femur had not shown any union it was considered a good solution to keep the existing plates and screws as they are.

In conclusion, prevention of periimplantar fracture in aged people is important however if one confronts a situation like this than Huckstep nail may be a good alternative.

 
   References Top

1.Platzer P, Schuster R, Aldrian S, Prosquill S, Krumboeck A, Zehetgruber I, et al. Management and outcome of periprosthetic fractures after total knee arthroplasty. J Trauma 2010;68:1464-70.  Back to cited text no. 1
[PUBMED]    
2.Ehlinger M, Bonnomet F, Adam P. Periprosthetic femoral fracture: The minimally invasive fixation option. Orthop Traumatol Surg Res 2010;96:304-9.  Back to cited text no. 2
[PUBMED]    
3.Huckstep RL. The Huckstep intramedullary compression nail. Indications, technique, and results. Clin Orthop Relat Res 1986;212:48-61.  Back to cited text no. 3
[PUBMED]    
4.Kim SK, Lee GB, Oh SJ, Ko CH. Rigid fixation with Huckstep nail in difficult femoral fractures. J Korean Orthop Assoc 1988;23:1313-24.  Back to cited text no. 4
    
5.Cho SH, Chung ST, Park HB, Ha YC, Kim BK, Jeong JH, Hwang SC, Huckstep nail in the treatment of a femur fracture. J Korean Orthop Assoc 2007;42:38-44.  Back to cited text no. 5
    
6.Christie J, Court-Brown C, Kinninmonth AW, Howie CR. Intramedullary locking nails in the management of femoral shaft fractures. J Bone Joint Surg Br 1988;70:206-10.  Back to cited text no. 6
[PUBMED]    
7.Lai KA, Shen WJ, Yang CY. Arthrodesis with a short Huckstep nail as a salvage procedure for failed total knee arthroplasty. J Bone Joint Surg Am 1998;80:380-8.  Back to cited text no. 7
[PUBMED]    
8.Choi NY, In Y, Yang YJ, Lim JI. Arthrodesis of the knee with a Huckstep nail following the treatment failure of an infected total knee arthroplasty. J Korean Knee Soc 2008;20:175-80.  Back to cited text no. 8
    
9.Hwang KS, Kim TS, Kim BH, Lee JM. Treatment of Shepherd's crook deformity with Huckstep's nail in fibrous dysplasia. J Korean Bone Joint Tumor Soc 2002;8:27-31.  Back to cited text no. 9
    

Top
Correspondence Address:
Ji Hyo Hwang
Department of Orthopedic Surgery, Kangnam Sacred Heart Hospital, Hallym University, College of Medicine, 948 1, Daerimdong, Yeongdeungpogu, Seoul 150 950
Korea
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0019-5413.104240

Rights and Permissions


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5]

This article has been cited by
1 Prevention of cement leakage into the hip joint by a standard cement plug during PFN-A cement augmentation: a technical note
M. Hanke,V. Djonov,M. Tannast,M. J. Keel,J. D. Bastian
Archives of Orthopaedic and Trauma Surgery. 2016; 136(6): 747
[Pubmed] | [DOI]
2 Intertrochanteric fractures: a review of fixation methods
Senthil Nathan Sambandam,Jayadev Chandrasekharan,Varatharaj Mounasamy,Cyril Mauffrey
European Journal of Orthopaedic Surgery & Traumatology. 2016; 26(4): 339
[Pubmed] | [DOI]
3 Anterior augmentation plating of aseptic humeral shaft nonunions after intramedullary nailing
Jan Gessmann,Matthias Königshausen,Marlon Osman Coulibaly,Thomas Armin Schildhauer,Dominik Seybold
Archives of Orthopaedic and Trauma Surgery. 2016; 136(5): 631
[Pubmed] | [DOI]
4 Cephalomedullary fixation for intertrochanteric fractures: an operative technical tip
Lin Jin,Liping Zhang,Zhiyong Hou,Wei Chen,Pengcheng Wang,Yingze Zhang
European Journal of Orthopaedic Surgery & Traumatology. 2014;
[Pubmed] | [DOI]



 

Top
 
 
 
  Search
 
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  
 


 
    Abstract
   Introduction
   Case Report
   Discussion
    References
    Article Figures
 

 Article Access Statistics
    Viewed3230    
    Printed50    
    Emailed2    
    PDF Downloaded112    
    Comments [Add]    
    Cited by others 4    