Tourniquet associated chemical burn


1 Department of Orthopedic Surgery, Seoul Veterans Hospital, Korea
2 Korea Orthopedic Clinic, Seoul, Korea

Click here for correspondence address and email

Date of Web Publication18-May-2012
 

   Abstract 

Chemical burn under pneumatic tourniquet is an iatrogenic preventable injury and is rarely reported in the literature. The two important mechanisms are maceration (friction) and wetness underneath the tourniquent. In this report, our experience with two illustrative patients who presented with iatrogenic tourniquet associated burn is described.

Keywords: Chemical burn, irritation, maceration, tourniquet

How to cite this article:
Yang JH, Lim H, Yoon JR, Jeong HI. Tourniquet associated chemical burn. Indian J Orthop 2012;46:356-9

How to cite this URL:
Yang JH, Lim H, Yoon JR, Jeong HI. Tourniquet associated chemical burn. Indian J Orthop [serial online] 2012 [cited 2019 Jun 24];46:356-9. Available from: http://www.ijoonline.com/text.asp?2012/46/3/356/96366

   Introduction Top


Pneumatic tourniquets have been commonly utilized during orthopedic extremity surgeries to attain a bloodless field facilitating operative procedures. Although tourniquet associated complications including postoperative swelling, delay of recovery of muscle power, compression neuropraxia, wound hematoma with the potential for infection, vascular injury, tissue necrosis, compartment syndrome, and systemic complications have been reported in the literature, the iatrogenic chemical burn during pneumatic tourniquet use has been rarely reported. [1],[2],[3],[4] Here, we report two cases of chemical burn to sensitize the orthopaedic surgeons about its possible occurrence.


   Case Reports Top


Case 1

A 24 year old male underwent lateral meniscus allograft transplantation on his left knee. The patient did not have thin skin and any underlying skin disease and allergies. The patient's operation was performed under tourniquet control. The tourniquet cuff used was a standard leg tourniquet (18 cm) and was applied with four layers of adequate wool padding. The skin preparation used was a 10% povidone-iodine (betadine) solution. The set pressure was 250 mmHg which was about 100 mmHg higher than the patient's systolic pressure. The tourniquet compression time was 2 h (total operation time=3 h). When the tourniquet was removed after operation, the burn was seen on the medial aspect of thigh [Figure 1]a. While inspecting the padding where the burn was present, the drape preparation seemed to have run down the patient's thigh during painting and had been left in wet condition underneath the tourniquet. The wound was of intermediate to deep second degree burn with blisters of size about 5 Χ 6 cm. The patient was treated conservatively with a furazone gauze occlusive dressing and was discharged from orthopedic department without skin grafting. However, he underwent multiple treatments with the dermatologist for complete healing which took almost 12 months [Figure 1]b. Even to this time (2 years postoperation), the patient continuously complains of hypersensitivity on the scar area, which aggravates during normal gait.
Figure 1: Case 1. Tourniquet-associated chemical burn developed on medial aspect of thigh: (a) immediate postoperative; (b) 1year and 9 months postoperative

Click here to view


Case 2

A 65 year old female patient, underwent elective unicompartmental knee arthroplasty for medial compartment osteoarthritis of the knee. The patient was free of chronic underlying diseases and had moderate skin thickness. The tourniquet cuff used was a standard leg tourniquet and was applied with four layers of adequate wool padding. The skin preparation used was a 10% povidone-iodine (betadine) solution. The set pressure was 250 mmHg which was about 100 mmHg higher than the patient's systolic pressure. The tourniquet compression time was 1.5 h (total operation time=2 h). When the tourniquet was removed, the burn was seen on the medial aspect of thigh. The burn was also of intermediate to deep second degree with dermis involvement. Betadine soaked padding was also observed at the site of burn. One week postoperatively, blisters and crusts were found roughly at the proximal margin of tourniquet [Figure 2]a. Local furazone gauze was applied for dressing and complete healing needed almost 1 year after operation. During this followup period, analgesics were continuously prescribed for the irritating, hypersensitive scar. Scar revision excising this hypersensitive, hypertrophic scar was needed after 1 year 4 months postoperatively [Figure 2]b.
Figure 2: Case 2. Tourniquet-associated chemical burn developed on medial aspect of thigh: (a) 1week postoperative; (b) 1year and 4months postoperative (just prior to scar excision)

Click here to view



   Discussion Top


The chemical burn resulting from tourniquet application cause more in-depth injury to the skin than the abrasion wound because there is greater time exposure and the anesthesia prevents the patient from reacting to the noxious burn stimulus. [5] Consequently, multiple debridement, skin graft, and even flap surgeries may be needed in such injuries with prolonged treatment period. Both of our cases had intermediate to deep second degree burn extending into deep dermis. Not only a long duration of healing time (up to 1 year postoperatively) was needed, but also hypersensitive and painful scar remained thereafter. The iatrogenic chemical burn induced by tourniquet application can have an impact on surgeon patient relationship.

Tourniquet associated chemical burns have been reported previously also. Dickinson and Bailey [1] reported four burns beneath the cuffs of pneumatic tourniquets. In all cases, the burns were seen when the tourniquet was removed. In two cases, the area of iodine staining corresponded exactly with the area of the burn, while in the other two cases the burns were smaller. All burns were of partial thickness and healed within 4 weeks, leaving minimal scarring. Nahlieli et al. [2] reported three adult cases. One of these patients had a partial thickness burn under the tourniquet cuff, after a 2-h surgery on his right palm. Similar experiences were reported by other authors. [3],[6] The scars described in these reports seem to have healed without much complications. Unlike the previous reported cases, our cases required prolonged healing time and patients continuously complained discomfort in the scar area.

The basic mechanism of tourniquet induced chemical burn involves irritation by antiseptics [2],[4],[7],[8] coupled with maceration, [9],[10],[11] compression pressure, [12],[13],[14] duration of compression, [13],[14] and wetness underneath the tourniquet. [15],[16] Polyvinylpyrrolidone-iodine (PI) is a widely used antiseptic which was introduced by Shelanski and Shelanski in 1965. [17] It is a water-soluble compound that results from the combination of molecular iodine and polyvinylpyrrolidone. The preparations of commercially available PI are povidone-iodine (betadine) solution, scrub, ointment, tincture, and foam; of these, the solution is the most commonly used. The 10% PI solution generally contains 90% water, 8.5% polyvinylpyrrolidone, and 1% available iodine and iodide (pH 4.5-5.5). Although uncommon, chemical burns have been reported with this solution. [2],[5],[18],[19],[20],[21] Alcohol (70%), which is used for draping, may also cause hypersensitivity. [2],[4],[7] By using alcohol, the epidermal lipid barrier acting to the skin may be decreased by de-esterification.

To prevent tourniquet associated chemical burn, two important points should be noted. First, friction between the skin and the tourniquet should be avoided because macerated skin becomes more permeable to PI which may become prone for damage. Movement of tourniquet during draping and compression should also be prevented. An elastic stockinette is known to be effective in preventing the development of maceration induced blisters. [22] The shape mismatch between the tourniquet and the thigh should be considered when applying tourniquet to minimize friction. Very muscular or obese patients tend to have conical shaped thigh. [14] Even distribution moving the skin and the soft tissues distally underneath the tourniquet may overcome this mismatch. Second, emphasis should be made on some form of barrier occluding the tourniquet, preventing wool soaking from antiseptics. [15],[16] In addition to a number of commercial covers, a variety of simple, non commercial alternatives have been proposed. Sarkhel and Stride [15] suggested using the disposable reservoir bag from a single use anesthetic circuit, while the use of surgical glove was proposed by Tomlinson and Harries. [16] Our department has been using adhesive plaster (Sinsin Pharm Co. Ltd., Korea) and antimicrobial incise drape (Ioban 2; , 3M Health care, USA) for mechanical barrier [Figure 3]a and b. On taking these precautions, further occurrence of tourniquet associated chemical burns was prevented.
Figure 3: Suggested method for tourniquet application with elastic stockinette and wool padding. Note the adhesive plaster (black arrow) (a) and antimicrobial incise drape (white arrow) (b) used for mechanical barrier

Click here to view


The chemical burn due to pneumatic tourniquet is a relatively under-reported problem which may be more frequent than believed. The PI related chemical burn in tourniquet use may be prevented by understanding the mechanism of occurrence of this complication to prevent this devastating iatrogenic injury.

 
   References Top

1.Dickinson JC, Bailey BN. Chemical burns beneath tourniquets. Br Med J 1988;297:1513.  Back to cited text no. 1
    
2.Nahlieli O, Baruchin AM, Levi D, Shapira Y, Yoffe B. Povidone-iodine related burns. Burns 2001;27:185-8.  Back to cited text no. 2
[PUBMED]  [FULLTEXT]  
3.Handley R. Chemical burns beneath tourniquets. Br Med J 1989;298:254.  Back to cited text no. 3
    
4.Chiang YC, Lin TS, Yeh MC. Povidone-iodine-related burn under the tourniquet of a child - a case report and literature review. J Plast Reconstr Aesthet Surg 2011;64;412-5.  Back to cited text no. 4
    
5.Hodgkinson DJ, Irons GB, Williams TJ. Chemical burns and skin preparation solutions. Surg Gynecol Obstet 1978;147:534-6.  Back to cited text no. 5
[PUBMED]    
6.Madhok R. Chemical burns beneath tourniquets. Br Med J 1989;298:254.  Back to cited text no. 6
    
7.Lowe DO, Knowles SR, Weber EA, Railton CJ, Shear NH. Povidone-iodine-induced burn: Case report and review of the literature. Pharmacotherapy 2006;26:1641-5.  Back to cited text no. 7
[PUBMED]  [FULLTEXT]  
8.Okano M. Irritant contact dermatitis caused by povidone-iodine. J Am Acad Dermatol 1989;20:860.  Back to cited text no. 8
[PUBMED]    
9.Bruner JM. Safety factors in the use of the pneumatic tourniquet for hemostasis in surgery of the hand. J Bone Joint Surg Am 1951;33:221-4.  Back to cited text no. 9
[PUBMED]    
10.Kutty S, McElwain JP. Padding under tourniquets in tourniquet controlled surgery: Bruner's ten rules revisited. Injury 2002;33:75.  Back to cited text no. 10
[PUBMED]  [FULLTEXT]  
11.McEwen JA, Kelly DL, Jardanowski T, Inkpen K. Tourniquet safety in lower leg applications. Orthop Nurs 2002; 21:55-62.  Back to cited text no. 11
[PUBMED]    
12.Delgado-Martinez AD. Pneumatic tourniquets in extremity surgery. J Am Acad Orthop Surg 2002;10:232.  Back to cited text no. 12
[PUBMED]  [FULLTEXT]  
13.Noordin S, McEwen JA, Kragh JF Jr., Eisen A, Masri BA. Surgical tourniquets in orthopaedics. J Bone Joint Surg Am 2009;91:2958-67.  Back to cited text no. 13
    
14.Wakai A, Winter DC, Street JT, Redmond PH. Pneumatic tourniquets in extremity surgery. J Am Acad Orthop Surg 2001;9:345-51.  Back to cited text no. 14
[PUBMED]  [FULLTEXT]  
15.Sarkhel T, Stride V. The Tourniqu Aid: Prevention of chemical burns. Injury 2002;33:73-4.  Back to cited text no. 15
[PUBMED]  [FULLTEXT]  
16.Tomlinson PJ, Harries WJ. The use of a surgical glove in the prevention of tourniquet-associated chemical burns. Ann R Coll Surg Engl 2008;90:255.  Back to cited text no. 16
[PUBMED]  [FULLTEXT]  
17.Shelanski HA, Shelanski MV. PVP-iodine: History, toxicity and therapeutic uses. J Int Coll Surg 1956;25:727-34.  Back to cited text no. 17
[PUBMED]    
18.Bayne D. Prevention of chemical burns. Ann R Coll Surg Engl 2008;90:715.  Back to cited text no. 18
[PUBMED]  [FULLTEXT]  
19.Hubik DJ, Connors A, Cleland H. Iatrogenic chemical burns associated with tourniquet use and prep solution. ANZ J Surg 2009;79:762.  Back to cited text no. 19
[PUBMED]  [FULLTEXT]  
20.Liu FC, Liou JT, Hui YL, Hsu JC, Yang CY, Yu HP, et al. Chemical burn caused by povidone-iodine alcohol solution - a case report. Acta Anaesthesiol Sin 2003;41:93-6.  Back to cited text no. 20
[PUBMED]    
21.Nakano S, Uchiyama A, Ueyama H, Nishimura M, Tashiro C, Azuma T. Chemical burn caused by povidone-iodine. Masui 1991;40:812-5.  Back to cited text no. 21
[PUBMED]    
22.Saleh KJ. An elastic stockinette under a pneumatic tourniquet protected against the development of blisters during total knee arthroplasty. J Bone Joint Surg Am 2007;89:459.  Back to cited text no. 22
[PUBMED]  [FULLTEXT]  

Top
Correspondence Address:
Jung-Ro Yoon
Department of Orthopedic Surgery, Seoul Veterans Hospital, 6 2 Dunchon Dong, Kangdong Ku, Seoul
Korea
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0019-5413.96366

Rights and Permissions


    Figures

  [Figure 1], [Figure 2], [Figure 3]

This article has been cited by
1 Povidone-iodine induced post-surgical irritant contact dermatitis localized outside of the surgical incision area. Report of 27 cases and a literature review
Leopoldo Borrego,Noelia Hernández,Zaida Hernández,Yeray Peñate
International Journal of Dermatology. 2016; 55(5): 540
[Pubmed] | [DOI]
2 Clinical and forensic signs related to chemical burns: A mechanistic approach
Ricardo Jorge Dinis-Oliveira,Félix Carvalho,Roxana Moreira,Jorge Brandão Proença,Agostinho Santos,José Alberto Duarte,Maria de Lourdes Bastos,Teresa Magalhães
Burns. 2014;
[Pubmed] | [DOI]
3 Pneumatic Tourniquet for Surgical Procedures of Hemodialysis Vascular Access
Shouwen Wang
Seminars in Dialysis. 2014; : n/a
[Pubmed] | [DOI]



 

Top
 
 
 
  Search
 
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  
 


 
    Abstract
   Introduction
   Case Reports
   Discussion
    References
    Article Figures
 

 Article Access Statistics
    Viewed2812    
    Printed86    
    Emailed2    
    PDF Downloaded80    
    Comments [Add]    
    Cited by others 3    

Recommend this journal