Results of cemented bipolar hemiarthroplasty for fracture of the femoral neck - 10 year study


Department Of Orthopaedics, Sir Ganga Ram Hospital, New Delhi, India

Click here for correspondence address and email
 

   Abstract 

Background : One of the most common treatments of displaced fracture of femoral neck in elderly is bipolar hemiarthroplasty.
Method : Two hundred and seventy patients of displaced fracture of femoral neck were treated by bipolar hemiarthroplasty. The Mean age of the patients at the time of surgery was 69.80 years.
Results : Follow up ranged between 12 months and 120 months. There were 8 cases each of acetabular erosion and protrusion with 10 cases of femoral stem loosening. Eight cases had post operative dislocation requiring open reduction. Eighteen patients got revision surgery to total hip replacement. The overall incidence of DVT/PE was 9.9% which declined after regular use of low molecular weight heparin. Eleven patients had post operative infection. There were 54.2 % excellent results, 21.0 % good results, 10.7 % fair and 3.7% poor results.
Conclusion : Elderly patients with displaced fracture of neck femur are able to ambulate early after Cemented bipolar hemi arthroplasty. The complication rate is low, the component survival long and pre injury functional status is restored in majority of patients.

Keywords: Displaced fracture femoral neck; cemented bipolar hemiarthroplasty

How to cite this article:
Maini P S, Talwar N, Nijhawan V K, Dhawan M. Results of cemented bipolar hemiarthroplasty for fracture of the femoral neck - 10 year study. Indian J Orthop 2006;40:154-6

How to cite this URL:
Maini P S, Talwar N, Nijhawan V K, Dhawan M. Results of cemented bipolar hemiarthroplasty for fracture of the femoral neck - 10 year study. Indian J Orthop [serial online] 2006 [cited 2019 Jun 16];40:154-6. Available from: http://www.ijoonline.com/text.asp?2006/40/3/154/34481

   Introduction Top


In geriatric population femoral neck fractures is one of the most common injuries. Prevalence of these fractures has further increased with improvement in life expectancy. The goal of treatment of these fractures is restoration of pre­fracture function without associated morbidity. But treatment of displaced femoral neck fractures in elderly has been controversial [1],[2],[3] . Open reduction and internal fixation of these fractures in elderly has poor outcome including high rate of non - union and avascular necrosis [1],[4] . Introduction of single piece unipolar metal prosthesis in 1950's, to replace the femoral head offered an alternative form of treatment [5],[6] . The problems encountered were acetabular erosion and loosening of stem giving rise to pain. In spite of these, superiority of prosthetic replacement over internal fixation was well established [7] . There is controversy at present whether to do hemiarthroplasty, bipolar or otherwise or primary THR in these cases. One of the aims of this study is to see whether bipolar hemiarthroplasty meets desired end result. As the bipolar hemiarthroplasty being quicker leading to lesser morbidity and low rate of dislocation which is quite common after primary THR in fracture of neck femur.

Bateman in 1974 introduced the prosthesis which had mobile head element and had additional head surface to allow movement within the acetabulum [8] . This led to reduced wear of acetabular surface and the prosthesis. The main aim to reduce immobilization and make patient walk early, with improved survival of implant is clearly met by this bipolar prosthesis.


   Materials and method Top


A total of 271 bipolar hemiathroplasty were done at authors' institution between Jan, 1993 and Dec, 2003 for displaced fracture of femoral neck. Few cases of nonunion and pathologic fracture due to metabolic neoplastic causes were also included in the study. This retrospective study was done looking into patient hospital record file, operative notes and progress sheet. At the end of study 75 patients had died while 196 patients were alive. Attempt was made to call all living patients to the hospital and evaluated them for pain and functional status. Radiographs of hip was obtained for each of them and compared with the first post operative X-ray. Few of these patients who could not come to our hospital were interviewed by telephone and their X-rays were requested by post. For the patients who were not alive interview of the relatives was done to know patients functional status and cause of death. First and last X-ray of these patients was requested by post. There were 133 fractures in the right hips and 138 fractures in the left hips. Total 144 fractures occurred in women and 127 fractures in male. Four patients had bilateral hemiarthroplasty and their first surgery was done in another hospital. These hips were not included in the study.

The oldest patient was 95 years old and the mean age being 69.80 years. However there was one case operated at the age of 24 years having pathological fracture due to fibrous dysplasia which was considered non reconstructable.

All cases were operated by Moore's posterior approach and done by consultants in the department. A total of 117 Indian prostheses (INOR modular) and 154 imported prostheses (Depuy Johnson, Zimmer & Sulzer) were used. All prostheses were of modular design with femoral component cemented.

The outer cup size was measured preoperatively on X­rays and again on table with measuring gauge and trial reduction was done. Between 1994 and 1997 in 58 hips manual (1 st generation) cementing technique was used. After 1997 pressurization and medullary canal plug (bone or Harding restrictors), were used in 213 cases. Preoperative prophylactic antibiotic was used in most patients. Before 1999 low molecular heparin was not used but later on it was routinely used. Post operatively dressing and drain removal was done after 48hrs and then ambulation was started with walker. Check X-ray was taken in all patients. Stitch removal was done at 12-14 days. Patients were called at 6 weeks postoperatively to repeat the X-rays. All patients were advised follow up every 6 months with X-ray or earlier in case of complaints. Follow up X-rays were assessed for acetabular protrusion, cartilage erosion, femoral component subsidence and loosening. Acetabular protrusion was determined by measuring medialization of the acetabular line compared with the normal hip or the first postoperative X-ray. Kohler or ilioischial line was used as reference. Acetabular cartilage erosion was determined by measuring change in thickness of acetabular cartilage as compared to first post operative radiograph or of the normal hip joint. Seven zones of Gruen et al were used to measure radiolucencies at prosthesis cement or cement bone interface. Distance between lesser trochanter and prosthesis collar was used to measure femoral component subsidence as compared to first postoperative X-ray.

Results were graded according to criteria keeping in patient's functional status during follow up in mind.

Grade 1 - No pain and limp or same as preoperative status of walking.

Grade II - Slight pain on extended walk or some limp.

Patient uses stick for support but are able to walk without it.

Grade III -Constant pain on walking and can walk only with support of stick or walker.

Grade IV - Not able to walk or bed ridden


   Results Top


Minimum follow up of 12 months was taken in the final reporting of the results. Twenty eight patients died within first 12 months of the study of which 10 died in early post operative period. The cause of death in each case was analyzed and these cases were removed from final grading of results. Maximum follow up was 120 months with mean follow up of 48.73 months. Average time period from injury to surgery was 9.12 days and average hospitalization after the surgery was 6.85 days of. Final evaluation of the results showed 75.3 excellent to good results according to criteria used [Table - 1].

Most common complication was electrolyte imbalance/ hyponatremia attributed to advanced age and medical problems. No correlation was found between time gap of injury and surgery with electrolyte imbalance and hyponatremia. All dislocations required open reduction. Closed reduction was first tried on OT table and four patients' modular head implant got dislodged [Table - 2]. Out of 26 patients of acetabular erosion, protrusion and femoral stem loosening, 18 patients got total hip replacement done. We started using low molecular weight heparin as routine in the year 1999. Between 1994 and 1998, 20 patients had DVT and PE. Frequency reduced to 5 patients in the year 1999 and 2003.


   Discussion Top


The treatment of femoral neck fractures in elderly has always been controversial. Scanning the literature shows various views on the treatments, some advocate internal fixation and others prosthetic replacement, whether unipolar or biopolar. Over all trend has fallen in favour of bipolar hemiarthroplasty due to early ambulation of elderly patient and less failure rate as compared to internal fixation. Lu-Yao et al in series of 106 cases found approximately threefold increase in re-operation if internal fixation was used compared to hemiarthroplasty for displaced femoral neck fractures in greater than 65 years old [9] . He had 33% nonunion and 16% avascular necrosis for patients treated with internal fixation. He found rate of re-operation was double when unipolar prosthesis is used. Lu - Yao et al further substantiated that total hip replacement is another excellent procedure but as high dislocation rate of 10.7% [9] . In our series of 271 patients the dislocation rate with bipolar hemiarthroplasty was 3%. [Table - 2] Further we had 3% incidence of acetabular erosion/ protrusion and 3.7% incidence of femoral loosening. Using modular design prosthesis can help us revised appropriate component if required.

We found no bearing on final results if Indian prosthesis like INOR modular or Depuy, Zimmer or Sulzer modular prosthesis were used. In first years of study we found increased incidence of DVT and PE where no low molecular weight heparin prophylaxis was used. We started using low molecular heparin after 1998 and incidence reduced dramatically.

All patients who were alive and relatives of dead patients were asked about over all patients satisfication with the procedure. 67.2 % were satisfied with the procedure. Most of the patients had retained there pre operative walking status. Sixty two patients were successfully squatting although against our advice.

We conclude that bipolar hemiarthroplasty is a good method to manage displaced femoral neck fractures in elderly.

 
   References Top

1.Asnis SE, Wande - Sgaglione L. Intracapsular fracture of the femoral neck - results of cannulated screw fixation. J Bone Joint Surg (Am).1994; 76: 1793-1803  Back to cited text no. 1    
2.Levine IS. Orthopaedic knowledge update - trauma. Am Acad Orthop Surg. 1996; 1: 113-119  Back to cited text no. 2    
3.Swiontkowski MF. Current concepts review - intra capsular fractures of the hip. J Bone Joint Surg (Am).1994; 76: 129-138  Back to cited text no. 3    
4.Rae PJ, Hodgkinson JP, Meadows TH, Davis DRA, Hargadon EJ. Treatment of displaced sub capital fractures with the Charnley - Hast­ing hemiarthroplasty. J Bone Joint Surg (Br). 1989; 71: 478 - 492  Back to cited text no. 4    
5.Moore AT. The self looking metal hip prosthesis. J Bone Joint Surg (Am).1957; 39: 811  Back to cited text no. 5    
6.Thompson FR. Two and a half years experience with a vitallium in­tramedullary hip prosthesis. J Bone Joint Surg (Am).1954; 36: 489 - 500  Back to cited text no. 6    
7.D' Arcy J, Devas M. Treatment of fractures of the femoral neck by replacement with the Thomson prosthesis. J Bone Joint Surg (Br). 1976; 58: 279-86  Back to cited text no. 7    
8.Bateman JE. Single assembly total limp prosthesis - Preliminary report. Orthop Digest. 1974; 2-15  Back to cited text no. 8    
9.Lu-Yao GL, Keller RB, Littenberg B, Wennberg JE. Outcomes after fractures of the femoral neck: A meta-analysis of one hundred and six published reports. J Bone Joint Surg (Am).1994; 76: 15-25  Back to cited text no. 9    

Top
Correspondence Address:
Manish Dhawan
Flat No-1345, Sector-A, Pocket-B&C, Vasant Kunj, New Delhi-110070
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0019-5413.34481

Rights and Permissions



 
 
    Tables

  [Table - 1], [Table - 2]

This article has been cited by
1 Is pre-operative assessment of coagulation profile with Thrombelastography (TEG) useful in predicting venous thromboembolism (VTE) following orthopaedic surgery?
Apurve Parameswaran,Vignesh P. Krishnamoorthy,Anil T. Oommen,Anita Jasper,Ravi J. Korula,Sukesh C. Nair,Pradeep M. Poonnoose
Journal of Clinical Orthopaedics and Trauma. 2016; 7: 225
[Pubmed] | [DOI]
2 Is it necessary to use chemoprophylaxis in Indian patients after hip surgery?
Chandra Prakash Pal,Amrit Goyal,Deepak Kumar,Rajendra Kumar Shakunt,Karuna Shankar Dinkar,Suneel Kumar
Journal of Clinical Orthopaedics and Trauma. 2016; 7(1): 30
[Pubmed] | [DOI]
3 Early Results of a Geriatric Hip Fracture Program in India for Femoral Neck Fracture
Deepak Jain,Guraziz Singh Sidhu,Harpal Singh Selhi,Simon C. Mears,Mohammad Yamin,Pankaj Mahindra,Harminder Singh Pannu
Geriatric Orthopaedic Surgery & Rehabilitation. 2015; 6(1): 42
[Pubmed] | [DOI]



 

Top
 
 
  Search
 
   
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  
 


 
    Abstract
    Introduction
    Materials and method
    Results
    Discussion
    References
    Article Tables
 

 Article Access Statistics
    Viewed8516    
    Printed152    
    Emailed11    
    PDF Downloaded491    
    Comments [Add]    
    Cited by others 3    

Recommend this journal